CN
Home > Products > Solar Cell System > DSR300 Micro-nano Device Spectral Response Measurement System

DSR300 Micro-nano Device Spectral Response Measurement System

DSR300 series micro-nano spectral response measurement system is dedicated to low-dimensional materials, providing high-precision spectral scanning and photo current scanning measurement. 40 m detection spot make the system can measure the minimum size 100 μm sample. Ultra-high stability light source provide the high accuracy; Multiple light sources can be integrated in the system to measure a variety of detectors. The friendly software is easy to use and automatically control the device to operate.
Inquiry
Download
Details

DSR300 series micro-nano spectral response measurement system is dedicated to low-dimensional materials, providing high-precision spectral scanning and photo current scanning measurement. 40 m detection spot make the system can measure the minimum size 100 μm sample. Ultra-high stability light source provide the high accuracy; Multiple light sources can be integrated in the system to measure a variety of detectors. The friendly software is easy to use and automatically control the device to operate.

Function:
■ Spectral Responsivity
■ External Quantum Efficiency
■ Bias Voltage IT Curve
■ LBIC Mapping
■ Response Linearity Test
Main Technical Parameter
Light Source

Xenon light Source

Supercontinuum light source

CW laser

Pulsed laser

 

Spectral Range: 250 - 1800 nm

Instability: < 1%

Spectral Range: 400

- 2400 nm

Frequency: 0.01 -

200 MHz

Pulse width: 100 ps

Optional Wavelength: 405 nm, 532 nm, 633

nm, 808 nm, 980 nm;

Instability: < 1%

Optional Wavelength: 375 nm, 405 nm, 488

nm, 785 nm, 976 nm; Pulse width: 100 ps

Frequency: 1-20 MHz

Micro lens

10x objective lens (Standard )

50x objective lens

50x UV objective lens

40x reflective objective lens

Work distance>17 mm

NA: 0.42

Spectral Range: 350

- 800 nm

Work distance>17 mm

NA: 0.42

Spectral Range: 480

- 1800 nm

Work distance>12 mm

NA: 0.42

Spectral Range: 240 - 500 nm

Work distance>7.8 mm

NA: 0.5

Spectral Range: 200 nm - 20 um

Data Acquisition Unit

Lock-in Amplifier

Keithley2612B

Keithley2636B

Frequency: 20 Hz - 1 KHz Drift: < 0.1°/℃ below 10 kHz Voltage or Current Input mode 1nV to 1V full-scale sensitivity Current gain 106 or 108 V/A Dynamic Reserve >100 dB Display: X、Y、R、θ

 

Current Range: 100 nA/ 1 A Minimum signal: 1 nA Noise: 100 pA

Resolution: 100 fA

Channel: 2

 

Current Range: 1 nA/ 1 A Minimum signal: 10 pA Noise: 1 pA

Resolution: 10 fA

Channel: 2

Cryostat

Temperature Range: -196℃ - 600℃

Temperature Resolution: 0.1℃

Clear Hole Diameter: 24mm

Sample Area: φ22mm

Working Distance: 4.5 - 12.5 mm

Air-tight sample chamber, can be filled with protective gas, independent temperature control.

Probe Station

4 probe holders with 20/10 micron tip

2 meters long triaxial cable, leakage current is less than 1 pA

Vacuum adsorption sample stage

X,Y, Z adjustable probe holder, 12mm travel range, 0.75um resolution

LBIC Maapping

XY travel range 50 mm, resolution 5 um, scanning spatial resolution: 1 um.


3D adjustable high stability probe station
The system can support four light paths, three are built-in light paths,one is external light path.
The external light path can provide tunable broadband monochromatic light.
Testing Curves:
The IV curves under different light intensities

Linearity test curve

Lifetime measurement curve(rise time, fall time)
40 um spot @ 550 nm @ 50 x objective lens with 200 um fiber
70 um spot @ 550 nm @ 50 x objective lens with 400 um fiber
5 um spot @ 375 nm picosecond pulsed laser @ 40 x objective lens
The monochromatic light energy output curves of UV enhanced xenon arc light source and EQ99 light source, with 40 x reflective objective lens, 300 mm focus length spectrograph under 1200 g/mm@ 300 nm blaze wavelength grating, spot diameter is 80 um.
Probe Light Power @1200/300